SF6 Recovery System
-
SF6 Gas Tester
-
SF6 Leak Detector
-
Gas Leak Detector
-
Dew Point Meter
-
Online Monitoring System
-
Dry Air Equipment
-
SF6 Vacuum Pump
-
Gas Mixing Unit
-
Refrigerant Recycling Machine
-
Refrigerant Leak Detector
-
SF6 Gas Purification
-
SF6 Accessories
-
Partial Discharge Detector
-
C4F7N Series Instruments And Equipment
-
Helium Mass Spectrometer
9V Electronic Refrigerant Leak Detector For SF6 R22 R410 R600 CO2 NH3 [KS-GB250]
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Detection Principle | Non-Dispersive Infrared Sensor | Sensitivity | 0.1ppm / 0.1g/a (Annual Leakage Rate) |
|---|---|---|---|
| Measurement Range | 0–100g/a (Annual Rate) / 0–1000ppm (Concentration) | Response Time | <1 S |
| Preheating Time | 2 Min | Repeatability | ±1% |
| Detectable Gases | '- LS-1: SF6, R22, R134a, R404, R407, R410, Hp-1, R1233ZD, - LS-2: R600, R290, LS-3: NH₃, - LS-4: CO₂ | ||
| Highlight | R600 Refrigerant Leak Detector,R410 Refrigerant Leak Detector,Electronic NH3 Leak Detector |
||
CH Refrigerant CO₂ NH3 Leak Detector - NDIR Sensor, 0.1ppm Sensitivity - SF6/ R22/ R410/ R600/ CO₂/ NH3 KS-GB250
Instrument characteristics
1. Adopting a non dispersive infrared sensor (NDIR) with strong anti-interference ability.
2. High detection sensitivity and good repeatability.
3. Adopting an embedded computer system, the instrument has strong stability and the sensor has automatic calibration function.
4. The measurement data and time can be saved and directly connected to a printer for printing or USB output.
5. Easy to operate, with full range digital direct reading of measurement data.
6. Equipped with alarm point setting device, sound and screen display digital color changing alarm.
7. The sampling electronic flowmeter can be directly read and observed on the screen, and abnormal flow can be alerted by the color change of the flow status icon.
8. The instrument adopts touch control and has a friendly human-machine interface.
Technical Parameter
Detection accuracy: 0.1g/a, 0.1ppm
Measurement range: 0-100g/a, 0-1000ppm
Response time:<1s
Preheating time: 2 minutes
Repetition accuracy: ± 1%
Gas detection:
LS-1:SF6,R22,R134a,R404,R407,R410,Hp-1,R1233ZD
LS-2:R600,R290
LS-3:NH3
LS-4:CO2
Display units: g/a, mL/s, Pam3/s, ppm
Alarm method: Sound alarm, screen display value changes color
Data output: RJ45, printer, USB flash drive
Usage environment: Temperature -20~50 ℃, humidity below 90% RH, no condensation
Usage posture: horizontal, stable
Working power supply: AC85-240V, 50/60Hz
Appearance dimensions: L280 × W260 × H180 (mm)
Instrument weight: approximately 2.5Kg