SF6/N2 Gas Mixture Analyzer with Chilled Mirror Dew Point Technology and High Precision Gas Composition Testing in Modular Design
| Place of Origin | SHANGHAI |
|---|---|
| Brand Name | KSTONE |
| Certification | ISO-9000 |
| Model Number | KS30-J9 |
| Document | KS30-J9-SF6-N2-Gas-Mixture-...or.pdf |
| Minimum Order Quantity | 1 |
| Packaging Details | Wooden box/ Carton box |
| Delivery Time | 15 work days |
| Payment Terms | T/T |
| Supply Ability | 1000 per year |
| SF₆ Accuracy | ±0.05% (90–100%) | N₂ Accuracy | ±0.5% (90–100%) |
|---|---|---|---|
| O₂ Accuracy | ±0.05% (90–100%) | Dew Point Accuracy | ±0.1℃ |
| SO₂ Accuracy | ≤±0.3 μL/L (≤10 μL/L) | H₂S Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
The KS30-J9 SF6/N2 Gas Mixture Analyzer is a high-precision analytical instrument based on chilled mirror dew point technology and modular gas analysis design. It is specifically developed for modern gas-insulated power systems using SF6/N2 mixed gases, providing comprehensive measurement of gas composition and insulation condition.
The system is capable of measuring:
- SF6 concentration
- N2 concentration
- Dew point (chilled mirror principle)
- SF6 decomposition products (SO₂, H₂S, CO)
With high stability and laboratory-grade accuracy, it is widely used in GIS substations, high-voltage switchgear, and gas quality monitoring applications.
Direct optical condensation measurement ensures ultra-high accuracy and long-term stability without sensor drift.
Simultaneous measurement of SF6, N2, moisture, and decomposition gases in one system.
SF6 accuracy up to ±0.05% and N2 accuracy up to ±0.03%.
Monitors SO₂, H₂S, and CO to evaluate insulation degradation and fault conditions.
Flexible structure for maintenance, calibration, and future expansion.
Designed for outdoor substation environments with temperature compensation and anti-interference capability.
Unlike traditional capacitive humidity sensors, chilled mirror technology measures dew point temperature by directly detecting condensation on a cooled mirror surface.
This ensures:
- No sensor aging or drift
- True physical measurement
- Extremely high repeatability
- Long-term calibration stability
It is widely regarded as the most accurate method for dew point measurement in high-end gas analysis systems.
| Parameter | Range | Accuracy | Repeatability |
|---|---|---|---|
| SF₆ | 0-100% | ±0.05% (90-100%) | ≤±0.03% |
| N₂ | 0-100% | ±0.5% (90-100%) | ≤±0.03% |
| O₂ | 0-1% | ±0.05% (0-1%) | ≤±0.03% |
| Parameter | Specification |
|---|---|
| Principle | Chilled Mirror |
| Range | -62℃ to Ambient Temperature |
| Accuracy | ±0.1℃ |
| Repeatability | ≤±0.1℃ |
| Parameter | Specification |
|---|---|
| Range | 0-100 μL/L |
| Extended Range | 0-2000 μL/L |
| Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Accuracy | ≤±3% (>10 μL/L) |
| Stability | ≤±0.2 μL/L |
| Repeatability | ≤±0.1 μL/L (≤10 μL/L) |
| Repeatability | ≤±1% (>10 μL/L) |
| Parameter | Specification |
|---|---|
| Range | 0-100 μL/L |
| Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Accuracy | ≤±3% (>10 μL/L) |
| Stability | ≤±0.2 μL/L |
| Repeatability | ≤±0.1 μL/L (≤10 μL/L) |
| Repeatability | ≤±1% (>10 μL/L) |
| Parameter | Specification |
|---|---|
| Range | 0-1000 μL/L |
| Accuracy | ≤±2 μL/L (≤50 μL/L) |
| Accuracy | ≤±4% (>50 μL/L) |
| Stability | ≤±1 μL/L |
| Repeatability | ≤±1 μL/L (≤50 μL/L) |
| Repeatability | ≤±2% (>50 μL/L) |
| Parameter | Value |
|---|---|
| Temperature Variation | -10℃ to +45℃ |
| SF₆ Drift | ≤±0.1% |
| SO₂ Drift | ≤±0.2 μL/L |
| H₂S Drift | ≤±0.2 μL/L |
| CO Drift | ≤±1 μL/L |
The KS30-J9 is widely used in:
- SF6/N2 gas insulated switchgear (GIS)
- Eco-efficient high-voltage substations
- Power transmission systems
- Gas-insulated circuit breakers
- Mixed gas quality monitoring
- Electrical utility maintenance
- Gas insulation research laboratories
- One System for Full Gas Analysis: Combines gas composition + moisture + decomposition analysis in a single platform.
- Designed for SF6/N2 Future Grid Technology: Supports modern eco-friendly gas insulation systems replacing pure SF6.
- High-End Measurement Accuracy: Laboratory-grade precision suitable for utility-grade diagnostics.
- Field-Ready Design: Stable performance in harsh outdoor substation environments.
| Feature | Chilled Mirror | Capacitive Sensor |
|---|---|---|
| Accuracy | High | Medium |
| Drift | None | Possible |
| Calibration Stability | Excellent | Limited |
| Long-Term Reliability | High | Medium |
It is a device used to measure the composition and insulation quality of SF6 and N2 mixed gases in electrical equipment.
Because modern eco-efficient GIS systems often use SF6/N2 mixtures to reduce environmental impact while maintaining insulation performance.
It is a method that determines dew point by directly observing condensation on a cooled mirror surface.
Yes, it measures SO₂, H₂S, and CO.
It is used in GIS substations, high-voltage switchgear, and power transmission systems.
- Professional gas detection equipment manufacturer
- Extensive HVAC and SF6 application experience
- OEM & customized solution support
- Fast technical response
- Stable industrial-grade product quality
- Global B2B export experience
The KS30-J9 is designed for advanced gas-insulated systems using SF6/N2 mixtures. It provides a comprehensive alternative solution for utilities requiring high-precision gas composition and insulation monitoring.