Product Details:
Payment & Shipping Terms:
|
| Power Supply: | 3V DC, 2×AA Alkaline Batteries | Maximum Sensitivity: | 14g/year (approved For R12, R22, R134a) |
|---|---|---|---|
| Ultimate Sensitivity: | <3g/year (for Halogen Refrigerants) | Probe Lifespan: | ~20 Hours (continuous Use) |
| Operating Temperature: | 0–52°C | Battery Life: | ~30 Hours (normal Operation) |
| Response Time: | Instantaneous | Reset Time: | 1 Second |
| Warm-up Time: | ~2 Seconds | ||
| Highlight: | Corona Discharge Gas Leak Detector,Electrochemistry Gas Leak Detector,Anti Fire gas sniffer detector |
||
| Parameter | Details |
|---|---|
| Power Source | 3V DC, 2×AA alkaline batteries (replaceable) |
| Maximum Sensitivity | 14g/year (certified for R12, R22, R134a) |
| Ultimate Sensitivity | <3g/year (for halogen refrigerants) |
| Probe Lifespan | ~20 hours (continuous operation) |
| Operating Temperature | 0–52°C (non-condensing) |
| Battery Life | ~30 hours (standard operation) |
| Response Time | Instantaneous |
| Reset Time | 1 second |
| Warm-up Time | ~2 seconds |
| Weight | 560g (portable design) |
| Dimensions (L×W×H) | 22.9×6.5×6.5cm |
| Probe Rod Length | 35.5cm (flexible access design) |
Contact Person: Ms. Jin
Tel: 15000093078