C4F7N Gas Mixture Analyzer - Measures C4F7N/CO2/O2/SF6/N2, Dew Point & Purity | High Accuracy, Portable AC/DC Dual-Use KS30-C4
Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xC4F7N Gas Mixture Analyzer - Measures C4F7N/CO2/O2/SF6/N2, Dew Point & Purity | High Accuracy, Portable AC/DC Dual-Use
The C4F7N Gas Mixture Analyzer is professionally designed for measuring the content of mixed gases such as perfluoroisobutyronitrile (C4F7N), carbon dioxide (CO2), and oxygen (O2), as well as detecting parameters like purity and dew point of mixed gases containing sulfur hexafluoride (SF6) and nitrogen (N2). It employs a high-speed microprocessor, a color touch screen display, and high-performance imported sensors. Multiple parameters can be measured in a single operation, significantly reducing user workload and improving efficiency. The instrument integrates multiple functions, including real-time measurement, power management, time management, file storage, and parameter settings.
Features:
1. Long-life detection components
2. High accuracy and excellent repeatability
3. Built-in pressure regulator and electronic flowmeter
4. Measurement results unaffected by ambient temperature
5. Fast measurement response speed
6. Color touch screen control with a graphical user interface for simpler operation
7. Test modes can be switched at any time
8. Direct digital readout of dew point / humidity / humidity at 20°C
Technical Parameters:
|
Measurement Range:0~20% Accuracy:≤±0.3% Resolution:0.01% Response Time:≤60S |
|
|
O2 |
Measurement Range:0~30% Accuracy:≤±0.5% Resolution:0.01% Response Time:≤60S |
|
CO2 |
Measurement Range:0~100% Accuracy:≤±0.5% Resolution:0.01% Response Time:≤3min |
|
SF6 |
Measurement Range:0~100% Accuracy:±0.5%(对标≤±0.2%) Resolution:0.01% Response Time:≤60S |
|
N2 |
Measurement Range:0~100% Accuracy:±0.5% Resolution:0.01% Response Time:≤60S |
|
O2 |
Measurement Range:0~1% Accuracy:±0.05% Resolution:0.001% Response Time:≤60S |
|
Dew Point |
Measurement Range:-60~+20℃ Accuracy:±1℃ Resolution:0.1℃ |
|
Sample Gas Flow |
0.5L/min |
|
Sample Gas Pressure |
≤10bar |
|
Ambient Conditions |
Temperature:-20℃~+50℃ Humidity:5~95%RH |
|
Power Supply |
Lithium battery; 100-240V AC, 50/60Hz (AC/DC dual-use) |
|
Dimensions |
414*333*177mm |
|
Weight |
7Kg |