All Products
-
SF6 Recovery System
-
SF6 Gas Tester
-
SF6 Leak Detector
-
Gas Leak Detector
-
Dew Point Meter
-
Online Monitoring System
-
Dry Air Equipment
-
SF6 Vacuum Pump
-
Gas Mixing Unit
-
Refrigerant Recycling Machine
-
Refrigerant Leak Detector
-
SF6 Gas Purification
-
SF6 Accessories
-
Partial Discharge Detector
-
C4F7N Series Instruments And Equipment
-
Helium Mass Spectrometer
Contact Person :
Jin
Phone Number :
15000093078
C4F7N Mixing Ratio Tester C4F7N CO2 O2 Moisture Content [KS30-C4-4]
| Pressure Measurement: | 0–1.0 MPa |
|---|---|
| Probe Protection: | Stainless Steel Sintered Filter Screen |
| C4 Humidity: | Dew Point -80~+20 °C |
C4F7N Leak Detector High-Precision Industrial Aerospace Use [LF-300-C4]
| Measurement Range: | 0.01ppm-100ppm(v) |
|---|---|
| Measurement Accuracy: | 0.1ppm(v) |
| Minimum Resolution: | 0.01ppm(v) |
Live Insulator Fault Partial Discharge Detector Tester 6kV-500kV With Laser Aiming [KS9001]
| Input Voltage: | AC 230V±10% |
|---|---|
| Input Frequency: | 50Hz±5% |
| Output DC Voltage: | DC 8.4V |
High Voltage Live Insulator Partial Discharge Ultrasonic Detector Dual Sensor ODM [KS9001]
| Center Frequency: | 40KHz±2Hz |
|---|---|
| Sensitivity: | Voltage:AC10kV Distance18MAC35kV Distance25MAC 110kV Distance 50M AC220-500kV Distance 50M |
| Operating Voltage: | 7.4V (lithium-ion Batteries*2pcs) |
Purification Device Can Obtain 99.99% SF6 Meeting The New Gas Standard Reducing Emissions, [KSLF-30WY20/63/100/N]
| Purification Efficiency: | 99.99% SF6 Concentration |
|---|---|
| Processing Capacity: | 6-20 Nm³/h (model-dependent) |
| Filtration Precision: | 0.1μm Particles, ≤3ppm Moisture |
9V Electronic Refrigerant Leak Detector For SF6 R22 R410 R600 CO2 NH3 [KS-GB250]
| Detection Principle: | Non-Dispersive Infrared Sensor |
|---|---|
| Sensitivity: | 0.1ppm / 0.1g/a (Annual Leakage Rate) |
| Measurement Range: | 0–100g/a (Annual Rate) / 0–1000ppm (Concentration) |
0.1ppm SF6 R22 Refrigerant Gas Leak Detector NDIR Sensor Touchscreen Control [KS-GB250]
| Sensitivity: | 0.1 Ppm |
|---|---|
| Dimensions & Weight: | 280×260×180mm (L×W×H), ~2.5kg |
| Response Time: | Less Than 1 Second |
[KS-GB250] CH Refrigerant Leak Detector | NDIR Sensor, 0.1ppm Sensitivity For CO₂/NH₃/SF6
| Detection Principle: | NDIR (Non-Dispersive Infrared) Sensor |
|---|---|
| Sensitivity: | 0.1ppm (Gas Concentration) / 0.1g/a (Annual Leakage Rate) |
| Measurement Range: | 0–100g/a (Annual Rate) / 0–1000ppm (Concentration) |
14l Automatic Refrigerant Recovery Machine 134a/12 For Auto Repair Shops [AC1000]
| Refrigerant Types: | R134a, R12 |
|---|---|
| Operating Temperature: | 5-50℃ |
| Maximum Pressure: | 18 Bar |
Automatic Gas Mixing Unit Distribution Dilution Device System, Flow Meters [KS3000-N]
| Flow Repeatability: | ≤± 0.5% |
|---|---|
| Flow Linear Error: | ≤± 0.3% |
| Gas Distribution Uncertainty: | ± 1% |

