Product Details:
Payment & Shipping Terms:
|
Storage Temperature: | -4-140°F | Dimensions: | 10.2 X 7.9 X 4.7 Inches |
---|---|---|---|
Model: | 3-033-R002 | Humidity Range: | 0-95% |
Sensitivity: | 1 Ppm | Power Supply: | 4 AA Batteries |
Display: | LCD | Warranty: | 1 Year |
Highlight: | 6kV Partial Discharge Detector,500kV Partial Discharge Detector,6kV tev partial discharge tester |
KS9001 Live Insulator Fault Detector | 6-500kV Partial Discharge Tester With Laser Aiming
In High Voltage Distribution Network, it usually causes the faults of flashover, grounding or porcelain explosion because of insulators degradation. So, it is important to detect and eliminate the faults of insulators, to ensure safe running of transmission and distribution line.
KS9001 Insulator Faults Detector is used to locate insulator faults in power plants and substation transmission lines under uninterrupted power state. It can also be used in partial discharge detection of electrical equipment, corona discharge detection, high voltage switch discharge detection and soon.
Detection items is as following,
1. Unknown flash over fault of live insulators (trip and switch on for many times)
2. Composite insulator failure
3. Oxidation discharge detection of HV connectors
4. Detect discharge caused by the poor connect of the switch in HV equipment
5. Corona discharge detection
6. Pollution flash over detection
Features
l Small size, light weight, novel and beautiful structure, full function, simple and fast operation , safe and reliable.
l For low or zero value insulators can automatically alarm. It is able to detect the insulator with leakage buthas not yet broken down at criticaldamage.
l Long-distance detection, laser aiming, accurate positioning of the deteriorated insulator and the specific location of its equipment failure, the accuracy rate is100%.
l Dual indication of stereo headphone and LCD display, the effect isobvious.
l Strong anti-interference ability.
l High degree of intelligence:
l With data locking function.
l Under-voltage function (If low voltage, the instrument will shut offautomatically).
l Constant current charging and auto stops by itself after fullcharge.
l Lithium-ionbatterywith1000chargingtimes,equippedwithintelligentchargingsystemto extend battery life.
Specifications
Main unit |
Center frequency |
40KHz±2Hz |
Sensitivity |
Discharge mode: pinpoint arc dischargeDischarge interval: 4mm |
|
Voltage:AC10kV distance18MAC35kV distance25MAC 110kV distance 50M AC220-500kV distance 50M |
||
Operating voltage |
7.4V (lithium-ion batteries*2pcs) |
|
Dimension |
250*125*140mm |
|
|
|
Output wavelength: 650nm |
Aluminum alloy |
Laser |
Divergency degree of light beam: 0.4mard Output power: ≤ 50mwDimension: 16*0mm |
Telescopic sight/Detachable handle/Tripod standard mounting screw hole |
||
bracket |
||
|
|
Center frequency (fo): 40kHz±2Hz |
|
High frequency sensor |
Center capacitance (Co): 2500±20%pF |
|
|
Working temperature: -20-60℃ |
|
|
Weight: 2.17kg |
Headphone |
Rated impedance (Z) |
125Ω |
Frequency range |
100Hz-10KHz |
|
Sensitivity |
(1W/1m) 60dB |
Charger |
Input voltage |
AC 230V±10% |
Input frequency |
50Hz±5% |
|
Output DC voltage |
DC 8.4V |
|
Current |
1A |
|
Packing dimension of whole set: 470*340*420mm |
||
Working temperature: -30-60℃; Humidity: (0~100) %RH |
||
Complete packing weight: 7.18kg |
Main Unit *1Power adapter (8.4V, 1A) *1 Headphone *1Tripod *1Battery charger for laser device *1 Handle *1Plastic case *1 User’s guide *1 Factory test report *1
Contact Person: Ms. Jin
Tel: 15000093078