All Products
-
SF6 Recovery System
-
SF6 Gas Tester
-
SF6 Leak Detector
-
Gas Leak Detector
-
Dew Point Meter
-
Online Monitoring System
-
Dry Air Equipment
-
SF6 Vacuum Pump
-
Gas Mixing Unit
-
Refrigerant Recycling Machine
-
Refrigerant Leak Detector
-
SF6 Gas Purification
-
SF6 Accessories
-
Partial Discharge Detector
-
C4F7N Series Instruments And Equipment
-
Helium Mass Spectrometer
Keywords [ sf6 gas recovery ] match 101 Products.
Sf6 Gas Analyzer Battery Operated Touchscreen, Emission-Free Comprehensive Tester [KS30-R-6]
| SF6 Gas: | [SO₂] 0~100 µl/l, [H₂S] 0~100 µl/l, [CO] 0~500 µl/l, [HF] 0~10 µl/l |
|---|---|
| SF6 Accuracy: | ±10% |
| SF6 Resolution: | 0.1 µl/l |
[LF-03-FR] SF6 Gas Leak Detector – NDIR Sensor, GB/T11023-2018 Certified
| Detection Method: | NDIR Non-dispersive Infrared (dual-beam) |
|---|---|
| Measurement Range: | 0-1000 PPM (customizable) |
| Accuracy: | ≤±2% F.S. (full-scale) |
Industrial Comprehensive Sf6 Gas Purity Test Analyzer Dew Point [KS30]
| H2S: | Accuracy: ≤±0.5% |
|---|---|
| SO2: | Accuracy: ≤±0.5% |
| CO: | Accuracy: ≤±0.5% |
Automatic SF6 Recycling System for GIS/GIL
| Features: | High Efficiency, Low Noise, Easy Operation |
|---|---|
| Application: | Gas Recovery |
| Vacuum Degree: | ≤5Pa |
SF6 Mixed Gas Analyzer for Dew Point Measurement SF6 Purity Analysis and Decomposition Gas Detection
| Dew Point Measurement Range: | -80°C ~ +20°C |
|---|---|
| Accuracy: | ±0.5% Or ±0.1% |
| SF6 Purity Measurement Range: | 0 ~ 100% |
Sulfur Hexafluoride SF6 Recovery System Gas Disposal Equipment 200L Customized
| Power Supply: | 3Φ 380V, 50Hz |
|---|---|
| Weight: | About 700 Kilograms |
| Vacuum Pump Limit Vacuum: | ≤0Pa |
Fully Automatic Recycling, Separation, And Purification Device, Capable Of Obtaining 99.99% SF6
| Purification Efficiency: | 99.99% SF6 Concentration |
|---|---|
| Processing Capacity: | 30-100 M³/h (model-dependent) |
| Filtration Precision: | 0.1μm Particles, ≤3ppm Moisture |
Portable Quantitative SF6 Leak Detector Gas Sensor 0.01ppm Sensitivity With Telescopic Handle
| Vacuum Pump Type: | Oil-Free Diaphragm Pump (Maintenance-Free) |
|---|---|
| Sensitivity: | 0.01ppm |
| Measurement Range: | 0.01–10,000ppm |
KS30 SF6 Comprehensive Tester: Dew Point, Purity & Decomposition Gas Detection with Customizable Modules
| SF6 Humidity Measurement Range: | Dew Point: -80~+20℃ (Supports Ppmv, Etc.) |
|---|---|
| Dew Point Accuracy: | ±1℃ |
| Response Time: | +20→-20℃ Td: 5s[45s], -20→-60℃ Td: 10s[240s] |
Kstone KS30-3 SF6 Tester: Precision Humidity, Purity & SO₂ Detection for Power Equipment Maintenance
| Response Time: | +20→-20℃ Td: 5s[45s], -20→-60℃ Td: 10s[240s] |
|---|---|
| Resolution: | Dew Point: 0.1℃ Or 0.1ppm |
| Gas Flow Rate: | 0.25~0.35L/min |